2 resultados para Aerobic

em QSpace: Queen's University - Canada


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Every aerobic organism expresses cytochrome c oxidase to catalyze reduction of molecular oxygen to water, and takes advantage of this energy releasing reaction to produce an electrochemical gradient used in cellular energy production. The protein SCO (Synthesis of cytochrome c oxidase) is a required assembly factor for the oxidase, conserved across many species. SCO is implicated in the assembly of one of two copper centres (ie., CuA) of cytochrome oxidase. The exact mechanism of SCO’s participation in CuA assembly is not known. SCO has been proposed to bind and deliver copper, or alternatively to act in reductive preparation of the CuA site within the oxidase. In this body of work, the strength and stability of Cu(II) binding to Bacillus subtilis SCO is explored via electronic absorption and fluorescence spectroscopies and by calorimetric methods. An equilibrium dissociation constant (Kd) of 3.5x10-12 M was determined as an upper limit for the BsSCO-Cu(II) interaction, via differential scanning calorimetry. In the first reported case for a SCO homolog, dissociation kinetics of Cu(II) from BsSCO were characterized, and found to be dependent on both ionic strength and the presence of free Cu(II) in solution. Further differential scanning calorimetry experiments performed at high ionic strength support a two-step model of BsSCO and Cu(II) binding. The implications of this model for the BsSCO-Cu(II) interaction are presented in relation to the mechanism of interaction between SCO and the CuA site of cytochrome c oxidase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The main objective of this pilot study was to investigate which standardized functional and physiological test best predicted perceived disability in a single group of 21 individuals diagnosed with osteoarthritis of the hip. Design: Men and women between 60 and 70 years old with osteoarthritis of the hip were selected. If participants passed study criteria, the Western Ontario McMaster University questionnaire (WOMAC), 6 Minute Walk Test (6MWT) and Timed up and Go (TUG), strength testing and aerobic testing were obtained in one single assessment. Results: Regression analysis revealed that wait time, hip abduction strength of the affected side, Aerobic Capacity (VO2 Peak), hip Extension Peak Torque, hip Flexion Peak Torque, TUG and 6MWT were significantly correlated with the WOMAC. Yet, the 6MWT had the highest significant correlation (r = -0.86, p ≤ 0.0001); R2 = 0.75 or 75% with the WOMAC total scores, (r = -0.82, p ≤ 0.0001); R2 = 0.67 or 67% with the WOMAC function and (r = -0.60, p = .002); R2 = 0.36 or 36% with the WOMAC stiffness. While the VO2 Peak revealed the highest significant correlation (r = 0.76, p ≤ .0001); R2 = 0.57 or 57% with the WOMAC pain. Conclusions: The 6MWT and the VO2 Peak seem to be essential functional and physiological assessment tools to determine perceived disability in individuals with hip OA. The perceived disability may provide new or comprehensive knowledge of the disability problems experienced by individuals with osteoarthritis of the hip, and the association of patient perception with objective measures of functional and physiological capacity might strengthen the clinical value of this knowledge.